15
6.4 Changing the set pressure
IMPORTANT: WHEN ADJUSTING SET PRESSURE, DO NOT EXCEED THE PRESSURE
CAPABLE OF THE DYNADRIVE IN THE INSTALLATION. REFERENCE TO LOCAL
REGULATIONS SHOULD ALSO BE CONSIDERED. When changing the set pressure of
DynaDrive, the pressure of the pressure tank must also be adjusted. Refer to section 4.5
pressure tank, of the installation chapter.
The set pressure cannot be changed while the pump is running, or in automatic mode.
To change the set pressure:
• Ensure automated control is turned off. To turn the automated control off, push the
Automatic on /
manual off button.
• The green
Automatic LED will turn off, see figure 6.5;
Figure 6.9
P/N:16115-1 BP/N:16115-1 B
Pset 60
Pact 60
• Once the motor has slowed to a stop, press and hold the Menu button for ~ 5 seconds. The display
will change to show your current set pressure, see figure 6.10;