20
To adjust both ON-TIME and OFF-TIME of TIMER 2:
70% – 09:35 AM
CHLORINE OUTPUT
Figure 12.10
> From the HOME screen, press menu/setting select;
> The display will show this screen:
MODE
1. TIMER 1
Figure 12.11
> Using the menu up/down buttons scroll to the TIMER 2 menu.
MODE
2. TIMER 2
Figure 12.12
> From this screen, press menu/setting select to enter TIMER 2 menu;
> To adjust both the ON-TIME and OFF-TIME for TIMER 2, follow the same steps shown previously
for TIMER 1.
12.3 ACTIVATING COVER MODE
A pool’s exposure to UV contributes significantly to the pool’s total chlorine demand. Ie the amount of
chlorine the pool uses. Excessive amounts of chlorine in a pool with a cover on, can significantly shorten the
life expectancy of the pool cover, if left for long periods of time (eg weeks). Turning on the COVER MODE
reduces the cell duty cycle by 80% of its current setting.
For example:
• If the ChloroMatic Nipper is on for 8 hours per day, the CHLORINE OUTPUT is set to 50%, but the COVER
MODE is on: the ChloroMatic Nipper cell duty cycle is only 48 minutes, of that day;