29
ALARM
LOW SALT CUT-OUT
Figure 12.34
Once the salt concentration is corrected, the LOW SALT CUT-OUT ALARM must be reset by pushing the
manual ON/OFF button. Alternatively, the ChloroMatic Nipper will conduct a system check automatically
when powered up the next time (if operating via a separate power supply). Upon start-up if the ChloroMatic
Nipper registers a salt concentration within range (refer to recommended salt range section in the manual),
the ChloroMatic Nipper will return to normal operation.
LOW SALT CUT-OUT ALARM is triggered at the following (approximate) salt concentrations:
ChloroMatic Nipper model Low salt cut-out alarm (approx. salt concentration)
DNP15CLS, DNP25CLS 1,200ppm
DNP15C, DNP25C, DNP35C 2,500ppm
12.11 ADD SALT ALARM AND LOW FLOW ALARM
Should the ChloroMatic Nipper register low flow and a salt concentration below its minimum (refer to
recommended salt range section in the manual), the ChloroMatic Nipper will alarm. The display will toggle
between the ADD SALT ALARM and the LOW FLOW ALARM. In LOW FLOW ALARM, the ChloroMatic
Nipper will not produce chlorine. As shown previously once faults are rectified, normal operation will resume.
12.12 OVERRIDING CLOCK SETTING
70% – 09:35 AM
CHLORINE OUTPUT
Figure 12.35
> From the HOME screen, press and hold menu/setting select for 3 seconds.