34
sliding gate 24V sliding gate 230V
OPERATORS
CONFIGURATION
PARAMETERS
Selectiontypeofoperators •005:LIVI5/24
•006:LIVI8/24
•007:GULLIVER/REV
Unusedparameter
Unusedparameter
OPERATING PARAMETERS
Operatorsspeedadjustmentduringslow-downwhileopening
Warning (230V only): For operators without
encoder,speedduringopening/closingcycles(100%)
and slow down speed during opening/closing cycles
(30%)arefixedindependentlyfromsetvalues.
15%tot........................100%tot
Operatorsspeedadjustmentduringthestrokewhileopening 15%tot........................100%tot
Operatorsspeedadjustmentduringthestrokewhileclosing 15%tot........................100%tot
Operatorsspeedadjustmentduringslow-downwhileclosing 15%tot........................100%tot
Slowdowndurationadjustmentwhileopening 5%tot............................80%to
Slowdowndurationadjustmentwhileclosing 5%tot............................80%tot
Operator1forceadjustmentwhileopening
(if=100%obstacledetectiondeactivated)
15%tot…...........................100%tot
Operatorn.1forceadjustmentwhileclosing
(if=100%obstacledetectiondeactivated)
15%tot…...........................100%tot
Unusedparameter
Unusedparameter
Automaticclosingtimesadjustment
(if=0automaticclosingdeactivated)
0sec...................................255sec
Pedestrianautomaticclosingtimeadjustment
(se=0pedestrianautomaticclosingdeactivated)
0sec...................................255sec
Pedestrianstrokedurationadjustment 5%tot…...........................100%tot
Pre-flashingtimeadjustment 0sec…….10sec
Unusedparameter
Unusedparameter
Collectivityfunction:ifitisactivateditdeactivatesbothopeningandclosinginputsforthewholedurationofautomaticopeningandclosing •000:“collectivityfunction”deactivated
•001:“collectivityfunction”activated
Ramblowfunction:itpushesthemotorsclosedforonesecondbeforeeachopeningmovement,soastoeasetheelectric-lockrelease •000:“ramblow”deactivated
•001:“ramblowfunction”activated
“Reversal”modeselection(duringthemanoeuvreacommandimpulsereversethemouvement)or“stepbystep”(duringthemanoeuvrea
commandimpulsestopsthemouvement).Anextimpulserestarttheoperatortotheoppositedirection.
•000:“reversalfunction”
•001:“stepbystepfunction
PHOTO1
PHOTOinputfunctioning:If=0:photocellenabledwhileclosingandstartingwhenthegateisstopped;if=1photocellsare
alwaysenabled;if=2photocellsareenabledwhileclosingonly.Whenenabled,itsactivationprovokes:theinversion(while
closing),thestop(whileopening)andpreventthestarting(whengateisclosed).
If=3-4-5,theoperationisthesameasthevalues0-1-2butwith“closeimmediately”enabled:inanycase,duringtheopening
and/orthepausetime,removalofapossibleobstaclecausesthegateautomaticallyclosesafterafixeddelayof5sec.
•000:photocellenabledwhileclosingandwhengateisstopped
•001:photocellsalwaysenabled
•002:photocellsenabledonlywhileclosing
•003:as000butwith“closeimmediately”enabled
•004:as001butwith“closeimmediately”enabled
•005:as002butwith“closeimmediately”enabled
PHOTO2