sliding gate 24V sliding gate 230V
OPERATING PARAMETERS
SAFETY1
OperationoftheSFTinput:if=0safetyedgealwaysenabled,if=1safetyedgeenabledonlywhileclosing,if=2safetyedge
enabledonlywhileclosingandbeforeanymovement,if=3safetyedgeenabledonlywhenopening,if=4safetyedgeenabled
onlywhileopeningandbeforeanymovement;asfortheobstacledetectionwithinternalanti-crushingsensor,alsotheactivation
oftheinputsSFT1andSFT2causesthecompleteorpartialreversalassetbyP055(durationofinversiononobstacleswhile
opening,andP056(durationofreversalonobstaclewhileclosing)
•000:“safetyedgealwaysenabled
•001:“safetyedgeenabledonlywhileclosing
•002:“safetyedgeenabledonlywhileclosingandbeforeanymovement
•003:“safetyedgeenabledonlywhenopening
•004:“safetyedgeenabledonlywhileopeningandbeforeanymovement
SAFETY2
Delayonlimitswitchdetection:theoperationisstoppedafter1,5secfromlimitswitchdetection.Whenduringthisdelayastopisdetected,
theoperatorissuddenlystopped
•000:“limitswitchdelaydisabled
•001:“limitswitchdelayenabled
Adjustmentofaccelerationdurability
Warning:ifsoftstartisactivated,theaccelerationisdeactivatedindipendentlyfromP070value.
• 000: “acceleration deactivated (it runs an acceleration of minimum durability,
almostimperceptible)
•00X:“adjuststheaccelerationdurabilityat1,5sec(X*6ms)
Unusedparameter
Unusedparameter
Unusedparameter
Unusedparameter
Unusedparameter