34
6  STANDARD PROGRAMMING
To access the control unit programming functions, remove the 
lid from the electric box and remove Jumper J4 from the bo-
ard.
NORMAL
FUNCTIONING
PROGRAMMING
MODE
1  Power Supply
When turned on, “ ”, “ ” (or the current rmware version) “ ”, “ ” appear on the display in sequence followed by the 
closed gate symbol “- - - - ”.
* If the control panel has already been programmed and the power fails or is switched off  - once power is returned and a START command 
is given, the position reset procedure is performed (see “rESP” in the table “WORKING STATUS MESSAGES” on page 41.
2  Motors stroke learning
ATTENTION: during the learning cycle there is no protection by the obstacles detection sensor!
1.  When you remove the Jumper J4, the display will shows P003;
2. Press 
 button to go on with the setting;
3.  As you see the message “
” blinking, verify the right door 
movements using the buttons   (OPEN) and   (CLOSE); 
  Attention: if the movement is not correct, switch off the 
power supply, invert the motor connections and repeat the 
check.
  Set the door in the position of total closure;
4.  Push the 
 button and hold it for 3 sec. (if you leave it before 
3 sec., the operation will be interrupted);
5.  Release the   button as soon as the “ ” message start 
blinking;
  Set the door in open position;
7.  Push the 
 button and hold it for 3 sec. (if you leave it before 
3 sec., the operation will be interrupted);
8.  Release the 
 button as soon as the “ ” message start 
blinking;
9.  An opening and closing manoeuvre will follow, at normal speed; 
at the end of the procedure the display will show P003.