EasyManua.ls Logo

Dea SPACE Series - Inputs Configuration Parameters; Programming Procedures

Dea SPACE Series
216 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
PAR. PROCEDURE SETTABLE VALUES
PROGRAMMING PROCEDURES
Unused parameter
Unused parameter
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Restoring the operating parameters
Lock access to programming
How to learn connected DE@NET devices (unused at the moment)
Restoring the “I/O” congurations (input/output)
Downloading data on the external memory unit
Uploading data from an external memory unit
Visualisation of inputs and operations-counter status
Unused parameter
Unused parameter
PAR. PARAMETER DESCRIPTION SETTABLE VALUES
DEFAULT VALUES
SPACE
SPACE
XL
SPACE
XXL
INPUTS CONFIGURATION PARAMETERS
INPUT_2 selectioning input type
• 000: IN2 type=free contact
• 001: IN2 type=constant resistance 8K2
Selection of pushbutton ▲ operation
Warning: select a value between 000 and 007
• 000: NONE (unused parameter)
• 001: START (start)
• 002: PED. (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSE (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSE_PM (man present close)
• 007: ELOCK_IN (congurable Output 2. See P062)
• 008: PHOTO 1 (photocell 1)
• 009: PHOTO 2 (photocell 2)
• 010: SAFETY 1 (safety rib 1)
• 011: STOP (lock)
• 012: FCA1 (opening limit switches Mot1)
• 013: Not Available
• 014: FCC1 (closing limit switches Mot1)
• 015: Not Available
• 016: SAFETY 2 (safety rib 2)
• 017: Not Available
• 018: Not Available
• 019: AUX_IN (congurable Output 1. See P066)
Selection of pushbutton ▼ operation
INPUT_1 operating selection IN1
INPUT_2 operating selection IN2
INPUT_3 operating selection IN3
INPUT_4 operating selection IN4

Table of Contents