shall be complete with pressure relief valve and associated shut-o valves in good working order. Empty recovery cylinders
are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instruons concerning the equipment that is at hand
and shall be suitable for the recovery of ammable refrigerants. In addon, a set of calibrated weighing scales shall be
available and in good wor
king order. Hoses shall be complete with leak-free disconnect couplings and in good condon.
Before using the recovery machine, check that it is in sasfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignin in the event of a refrigerant release. Consult manufacturer if
in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, a
nd the relevant Waste
Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make
certain that mmable refrigerant does not remain within the lubricant. The evacuaon process shall be carried out prior to
returning the compressor to the suppliers. Only electric heang to the compressor body
shall be employed to accelerate this
process. When oil is drained from a system, it shall be carried out safely.
Appendix
Schemadiagram of the air-condoner
For specitechnical parameters of the model, refer to rang label on the product.
Correct Disposal of this product
This marking indicates that the product should not be disposed with other household wastes. To prevent possible harm to the
environment or human health from uncontrolled waste
disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and colleon systems or contact the retailer where the product was
purchased. They can take this product for environmentally safe recycling.
Evaporator
Condenser
Compressor
Capillary
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
43
44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65