EasyManua.ls Logo

Defensor PH15 - Operating modes and buzzer control

Defensor PH15
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Buzzer
Off
Buzzer
New Value
Buzzer
Old Value
Buzzer
Off
5.4.4 Switching the buzzer on and off
(see chapter 5.4.3)
(see chapter 5.4.5)
modify
confirm
cancel
On or Off
Available settings: On (buzzer on) or Off (buzzer off)
Factory setting: Off
Notes on setting: If the buzzer is on an acoustic signal is triggered in case of a malfunction or
an irregularity during operation.
Humidifying mode
Humidify
Humidifying mode
New Value
Humidifying mode
Old Value
Humidifying mode
Humidify
5.4.3 Selecting the operating mode (Humidifying mode)
(see chapter 5.4.2)
(see chapter 5.4.4)
modify
confirm
cancel
Humidify, Purify, Off
Note: The humidifying mode can be modified only if program mode is deactivated (see chapter 5.5).
Available settings: Humidify (air humidification), Purify (air purification with humidification) and
Off (air purification without humidification)
Factory setting: Humidify
Notes on setting: The selection of the humidifying mode depends on whether the Defensor
PH15/PH15A shall be operated as humidifier, as purifier with humidification
or as purifier without humidification. If the unit shall be operated as purifier
without humidification the base tub and the water tank should be emptied.