DelfiScan
Programming Manual
Configure Your DelfiScan
38
PROGR
AM
Operation Control
Flash Duty Cycle, Redundancy, Delay Setting
M_DEF
AULT
Family Code Selection P.C Parameter Selection Option Code
Flash Duty Cycle
SS
SS
SS
SS
1/2 duty cycle
2/3 duty cycle
3/4 duty cycle
4/5 duty cycle
0
1
2
3
Redundancy (Scan Voting)
SS
SS
SS
SS
SS
SS
None
Level 1
Level 2
Level 3
Level 4
Level 5
To prevent potential miss reading.
0
1
2
3
4
5
Reread Delay
SS
SS
SS
SS
SS
SS
Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification
0
1
2
3
4
5
Good Read Delay
SS
SS
SS
SS
SS
SS
SS
None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
0
1
2
3
4
5
6
The
Flash Duty Cycle
is designed to control the flashing frequency of the light source
.
The
Re
dundancy
is the number of times the same bar code label has to be decoded befo
re it is transmitted.
The
Rerea
d Delay
is designed to inhibit DelfiScan from reading the same bar code label twice in pre-defined short duration. Force Verification
will not
allow reading of the same ba
r code
twice.
This
Good Read
Delay
is the minimum amount of time before the imager can read another bar code.