4 Type the command fs0:/fs1: to enter the le system and locate the le.
NOTE: File system partitions may vary depending on your system conguration. Browse through the fsx to locate the USB
disk.
5 Run the le run.nsh to ash the rmware.
6 On successful update of rmware type Exit to exit from the UEFI shell and reboot the system.
7 Verify the installed rmware version in HII, iDRAC or BOSS-S1 CLI.
Firmware update using BOSS-S1 CLI
Download the appropriate CLI application le from Dell.com/support for your Windows or Linux operating system.
Firmware update using Windows
Following are the steps to update the rmware using the BOSS-S1 command line interface.
1 Download the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip from Dell.com/support and extract the zip le.
2 Open the vs2015/windows folder. Example: C:\Desktop\mvsetup.xxxxx_Axx\windows\x64\cli
3 Copy the rmware image binary from the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip folder to the directory where CLI le is located.
Overwrite any existing les.
NOTE: BOSS-S1 supports multiple sub device ID. Locate the correct sub device ID which is available in the iDRAC, BOSS-S1
HII, and BOSS-S1 OS CLI (Info -o hba).
Table 3. Supported SubDevice ID
SubDevice ID Firmware Binary Link
1FD6 (Monolithic) ImageA1_1FD6.bin
1FE2 (Monolithic) ImageA1_1FE2.bin
1FDF (Modular) ImageA1.bin
4 Run mvsetup.exe.
5 To ash the rmware, run the command flash –a update –f ImageA1_xxxx.bin –t raw in the CLI shell.
6 Exit and reboot the system, and verify the rmware version.
NOTE
: Administrator privileges for Windows and Root/Sudo for Linux are recommended.
Firmware update using Linux
Perform the following steps to update your rmware using the Linux BOSS-S1 command line interface (CLI):
1 Download the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip from Dell.com/support.
2 Locate the folder which contains the downloaded the CLI le, for example: C:\Home\Desktop\mvcli.xxxx_Axx\x64\cli.
3 Copy the rmware image binary from the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip folder to the directory where the CLI le is
located. Overwrite any existing les.
NOTE
: The BOSS-S1 card supports multiple subdevice IDs. Locate the correct subdevice ID, available in the iDRAC, BOSS-
S1 HII, and BOSS-S1 operating system CLI (Info -o hba).
10 Overview

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC Boot Optimized Server Storage-S1 and is the answer not in the manual?

Dell EMC Boot Optimized Server Storage-S1 Specifications

General IconGeneral
BrandDell EMC
ModelBoot Optimized Server Storage-S1
CategoryServer
LanguageEnglish

Related product manuals