Parameter Specications
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature –40°F to 70°C (–40°F to 158°F)
Storage humidity 5% to 95%, non-condensing
Maximum thermal output 300 W = 1024 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock SV0115 — ODM
Table 6. AC power requirements
Parameter Specications
Power supply 100–240 VAC 50/60 Hz
Typical current draw per platform
• 110VAC: 1.8A (16 core) 240VAC: 0.85A (16 core)
• 110VAC: 1.5A (8 core ) 240VAC: 0.7A (8 core)
• 110VAC: 1.35A (4 core) 240VAC: 0.65A (4 core)
Maximum power capability
• 5-fan 16-core processor: 300W
• 4-fan 8-core processor: 230W
• 4-fan 4-core processor: 220W
Typical power consumption
• 5-fan 16-core processor: 200W
• 4-fan 8-core processor: 170W
• 4-fan 4-core processor: 160W
IEEE standards
The VEP4600 platform complies with the following IEEE standards.
• 802.1ab (LLDP)
• 802.1ax (Layer 2)
• 802.1d, 802.1w, 802.1s, 802.1x (Mgmt/Security), 802.3x (Layer 2)
• 802.3 (1000BASE-KX)
• 25G Etherenet Consortium 25
Agency compliance
The VEP4600 is designed to comply with the following safety and agency requirements:
USA Federal Communications Commission statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance to the
30