186 Brocade Adapters Installation and Reference Manual
53-1002144-01
Converged Network Adapters
5
Mezzanine CNAs
This section provides specifications for mezzanine CNAs.
Brocade 1007 CNA
Table 23 lists environmental and power specifications for the Brocade 1007 CNA.
The Brocade 1007 adapter conforms to environmental and power specifications for the supported
blade servers and blade system enclosures where they install. Refer to the documentation
provided for these products for information. Also refer to “Server blades and blade system
enclosures (mezzanine adapters)” on page 11.for references to CNA compatibility information.
Brocade 1741 CNA
Table 24 lists environmental and power specifications for the Brocade 1741 CNA.
TABLE 23 Environmental and power requirements for Brocade 1007 CNA mezzanine card
Property Requirement
Airflow Provided by blade system enclosure.
Altitude Operating - 3,048 meters (10,000 ft.)
Nonoperating - 12,193 meters (40,000 ft.)
Operating Temperature 0 to 50 °C (32 to 122 °F)
Nonoperating Temperature Maximum: 73 °C (163 °F)
Minimum: -40 °C (-40 °F)
Operating Humidity 50 °C (122 °F) at 10% to 93%
Nonoperating Humidity 60 °C (140 °F) at 10% to 93%
Power Dissipation 9.5 W maximum
8.5 W nominal
Operating Voltage Per PCIe 2.0 specifications
Dimensions Approximate height: 13 mm (0.5 in)
Approximate width: 160 mm (6.3 in)
Approximate depth: 124 mm (4.9 in)
Approximate weight: 127 g (0.28 lb)
TABLE 24 Environmental and power requirements for Brocade 1741 CNA mezzanine card
Property Requirement
Airflow Provided by blade system enclosure.
Altitude Operating - 3,048 meters (10,000 ft.)
Nonoperating - 10,600 meters (35,000 ft.)
Operating Temperature 0 to 35°C (32 to 95°F)
Nonoperating Temperature Maximum: 65°C (149 °F)
Minimum: -40 °C (-40 °F)
Operating Humidity 35 °C (95 °F) at 20% to 80%
Nonoperating Humidity 65 °C (149 °F) at 5% to 95%
Power Consumption 15 W required
12 W measured