Upgrade Dell EMC Networking N3000E-ON Switches
Page 5
Upgrade Stack of Dell EMC Networking N3000E-ON Switches – Advanced Version
Note on “copy command from steps 2,3 and 4 in switch upgrade above:
“copy” command will take longer to complete with a stack of switches. This is due to the master switch
copying the software to the member switches. The master switch will display the line “Distributing the
code to the members of the stack!” for several minutes until the copy is done.
“copy” command will copy the software to all the switches as “backup” image
console#show version
Machine Description............... Dell EMC Networking Switch
System Model ID................... N3048EP-ON
Machine Type...................... Dell EMC Networking N3048EP-ON
Serial Number.....................
Manufacturer...................... 0xbc00
Burned In MAC Address............. 0090.BC06.A571
System Object ID.................. 1.3.6.1.4.1.674.10895.3060
SOC Version....................... BCM56340_A0
HW Version........................ 5
CPLD Version...................... 20
Image File........................ N3000Advv6.5.3.36
Software Capability............... Stack Limit = 12, VLAN Limit = 4093
unit active backup current-active next-active
---- ----------- ----------- -------------- --------------
1 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
2 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
3 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
console# boot system backup
Activating image backup ..
console#show version
Machine Description............... Dell EMC Networking Switch
System Model ID................... N3048EP-ON
Machine Type...................... Dell EMC Networking N3048EP-ON
Serial Number.....................
Manufacturer...................... 0xbc00
Burned In MAC Address............. 0090.BC06.A571
System Object ID.................. 1.3.6.1.4.1.674.10895.3060
SOC Version....................... BCM56340_A0
HW Version........................ 5
CPLD Version...................... 20
Image File........................ N3000Advv6.5.3.36
Software Capability............... Stack Limit = 12, VLAN Limit = 4093
unit active backup current-active next-active
---- ----------- ----------- -------------- --------------
1 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
2 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
3 6.5.3.36 6.5.3.36 6.5.3.36 6.5.3.36
console#reload
Management switch has unsaved changes.
Are you sure you want to continue? (y/n) y
Configuration Not Saved!
Are you sure you want to reload the stack? (y/n) y
After the stack of switches has finished rebooting, log in and verify that the firmware has been updated to the
6.5.3.36 version using the show version command. A single switch will typically reboot in around two minutes. A
stack may take significantly longer to complete the upgrade process.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC PowerSwitch N3000E-ON Series and is the answer not in the manual?

Dell EMC PowerSwitch N3000E-ON Series Specifications

General IconGeneral
BrandDell
ModelEMC PowerSwitch N3000E-ON Series
CategorySwitch
LanguageEnglish

Related product manuals