Loading...
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
RFcache API
mismatch
RFCACHE_API_ERROR
_MISMACH
SDS.SDS.RFCA
CHE_API_ERR
OR_MISMACH
SIO03.01.000
0013
2 (Warning) The Read Flash Cache
(xcache) driver version and
SDS version do not match.
Try to upgrade them to the
same version. If the
problem persists, contact
Customer Support.
SDS is in
Maintenance Mode
SDS_IN_MAINTENANC
E
SDS.SDS.SDS_
IN_MAINTENA
NCE
SIO03.01.000
0014
2 (Warning) The SDS is currently in
Maintenance Mode. Exit
Maintenance Mode once
maintenance is complete. If
an NDU is in progress,
ignore this warning.
Device failed DEVICE_FAILED SDS.Device.De
vice_Failed
SIO03.02.000
0001
3 (Error) The SDS device could not
be opened, read from or
written to. Validate the
device state. Check the
cause of the error, and
determine if it is a human
error or a system
malfunction. Check
hardware if needed.
Device test is done
and device is
pending activation
DEVICE_PENDING_ACT
IVATION
SDS.Device.De
vice_Pending_
Activation
SIO03.02.000
0002
2 (Warning) The SDS device has been
added and tested. Activate
the SDS device.
Device has fixed
read errors
FIXED_READ_ERROR_
COUNT_ABOVE_WARN
ING_THRESHOLD
SDS.Device.FIX
ED_READ_ERR
OR_COUNT_A
BOVE_WARNI
NG_THRESHO
LD
SIO03.02.000
0003
3 (Error) if
counter > 0
Read from the SDS device
failed. Data was corrected
from the other copy. No
action is required, but note
that the device might be
faulty.
Device has fixed
read errors
FIXED_READ_ERROR_
COUNT_ABOVE_CRITI
CAL_THRESHOLD
SDS.Device.FIX
ED_READ_ERR
OR_COUNT_A
BOVE_CRITICA
L_THRESHOLD
SIO03.02.000
0004
5 (Critical) if
counter >= 5
SDS device read failed
more than 5 times. Replace
the physical device.
Device failed: All IO
to the device will be
stopped, and data
will be relocated to
another device.
DEVICE_ERROR_ERRO
R
SDS.Device.De
vice_ErrorError
SIO03.02.000
0005
5 (Critical) Check the device, and if
necessary, replace it
Device failed: All IO
to the device will be
stopped, and data
DEVICE_ERROR_WARN
ING
SDS.Device.De
vice_ErrorWarn
ing
SIO03.02.000
0006
3 (Error) Check the device, and if
necessary, replace it