Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
will be relocated to
another device.
Device malfunction
has been detected.
DEVICE_ERROR_NOTIC
E
SDS.Device.De
vice_ErrorNotic
e
SIO03.02.000
0007
2 (Warning) Check the device, and if
necessary, replace it
Minor failures have
been detected in
device performance.
DEVICE_ERROR_INFO SDS.Device.De
vice_ErrorInfo
SIO03.02.000
0008
2 (Warning) Check the device, and if
necessary, replace it
The SDC is either
down or unreachable
over the network
SDC_DISCONNECTED SDC.SDC.SDC
_DISCONNECT
ED
SIO04.01.000
0001
3 (Error) Verify that the SDC service
is up and running and that
the network is properly
configured and connected.
No more SDCs can
be defined on this
system; the
maximum has been
reached
SDC_MAX_COUNT SDC.SDC.SDC
_Max_Count
SIO04.01.000
0002
3 (Error) The maximum number of
SDCs in the system has
been reached (1024^2).
SSD lifespan is over
endurance threshold
PHYSICAL_DRIVE_END
URANCE_USED_ABOV
E_THRESHOLD
Storage_Contr
oller.Physical_D
rive.Endurance
_Used_Above_
Threshold
SIO06.01.000
0004
5 (Critical) Replace the SSD device.
The Physical Disk
temperature has
exceeded the
configured threshold
PHYSICAL_DRIVE_INVA
LID_TEMPERATURE
Storage_Contr
oller.Physical_D
rive.INVALID_T
EMPERATURE
SIO06.01.000
0005
5 (Critical) 3
(Error)
Ensure that the server and
its environment are
properly cooled. Ensure
that the internal chassis
fans are working, and that
there is adequate airflow.
The Physical Drive's
cache is not disabled
PHYSICAL_DRIVE_INVA
LID_PD_CACHE_POLIC
Y
Storage_Contr
oller.Physical_D
rive.INVALID_P
D_CACHE_POL
ICY
SIO06.01.000
0006
3 (Error) Disable the Physical Drive
physical cache. Note: This
may cause DI issues in
power cycle scenarios.
Device was
requested to use as
DAS Cache but it is
not
DEVICE_SHOULD_USE
_AS_DAS_CACHE_BUT
_IT_IS_NOT
Storage_Contr
oller.Physical_D
rive.Device_Sh
ould_Use_As_D
as_Cache_But_
It_Is_Not
SIO06.01.000
0007
3 (Error)
The Logical Disk
read policy is not set
to "Read-Ahead"
LOGICAL_DISK_INVALI
D_READ_AHEAD_POLI
CY
Storage_Contr
oller.Logical_Di
sk.INVALID_RE
AD_AHEAD_P
OLICY
SIO06.02.00
00001
3 (Error) Access the storage
controller and change the
Logical Disk's read policy to
"Read Ahead".
SNMP Trap Support