Upgrade Dell EMC Networking N1500 Series Switches  
 
 
Page 9 
 Upgrade Stack of Dell EMC Networking N1500 Series Switches 
 
Note on “copy” command from steps 2,3 and 4 in switch upgrade above: 
  “copy” command will take longer to complete with a stack of switches. This is due to the master switch 
copying the software to the member switches. The master switch will display the line “Distributing the 
code to the members of the stack!” for several minutes until the copy is done.   
  “copy” command will copy the software to all the switches as “backup” image 
 
console#show version 
Machine Description............... Dell Networking Switch 
System Model ID................... N1548P 
Machine Type...................... Dell Networking N1548P 
Serial Number..................... 15114M0002LF 
Manufacturer...................... 0xbc00 
Burned In MAC Address............. 001E.C9E5.BD0F 
System Object ID.................. 1.3.6.1.4.1.674.10895.3066 
SOC Version....................... BCM56150_A0 
HW Version........................ 1 
CPLD Version...................... 16 
 
unit active      backup      current-active next-active 
--- ----------- ----------- -------------- -------------- 
1    6.3.3.14     6.5.2.9     6.3.3.14        6.3.3.14 
2    6.3.3.14     6.5.2.9     6.3.3.14        6.3.3.14 
3    6.3.3.14     6.5.2.9     6.3.3.14        6.3.3.14 
4    6.3.3.14     6.5.2.9     6.3.3.14        6.3.3.14 
 
console# boot system backup 
Activating image backup .. 
 
console#show version 
System Model ID................... N1548P 
Machine Type...................... Dell Networking N1548P 
Serial Number..................... 15114M0002LF 
Manufacturer...................... 0xbc00 
Burned In MAC Address............. 001E.C9E5.BD0F 
System Object ID.................. 1.3.6.1.4.1.674.10895.3066 
SOC Version....................... BCM56150_A0 
HW Version........................ 1 
CPLD Version...................... 16 
 
unit active      backup      current-active next-active 
--- ----------- ----------- -------------- -------------- 
1    6.3.3.14     6.5.2.9     6.3.3.14        6.5.2.9 
2    6.3.3.14     6.5.2.9     6.3.3.14        6.5.2.9 
3    6.3.3.14     6.5.2.9     6.3.3.14        6.5.2.9 
4    6.3.3.14     6.5.2.9     6.3.3.14        6.5.2.9 
 
console#reload 
Management switch has unsaved changes. 
Are you sure you want to continue? (y/n) y 
Configuration Not Saved! 
Are you sure you want to reload the stack? (y/n) y 
 
After the stack of switches has finished rebooting, log in and verify that the firmware has been 
updated to the 6.5.2.9 version using the show version command. A single switch will typically 
reboot in around two minutes. A stack may take significantly longer to complete the upgrade 
process.