EasyManua.ls Logo

Dell Networking 7048 - K N O W N R E S T R I C T I O N S a N D L I M I T a T I O N

Dell Networking 7048
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.0.1 Page 67
Known Restrictions and Limitations
Release 5.1.0.1
Description User Impact
SNMP walk is not successful while doing walk on root port Low
SNMP walk on root port may result in a
timeout if executed without specifying any
timeout value.
Workaround:
Execute walk with a recommended timeout
value of 2 sec
The IPMC L2_BITMAP is only updated to reflect ports that should 'not' be
flooded when a multicast stream is 'first' seen on a VLAN.
Moderate
There will be some flooding of multicast
traffic
Workaround: Issue no ip multicast followed
by ip multicast
"ip http secure-server" may not be cleared after performing the clear config
operation if there is user intervention before prompt returns
Low
Clear config operation clears all system
components operational and configuration
information and then builds the default
configuration. This operation takes time to
complete and the prompt may not be returned
immediately. Prompt is returned after the
completion of the operation. Please wait for
the prompt, pressing "enter"/CR is not
needed in this case.
Workaround: Issue clear config one more
time if “ip http secure-server” configuration
is not cleared
Reboot needed when critical message “Failed to add local route for network
X/X on interface X” appears on the console
High
Route is not added and hence critical
situation. Need a reboot to recover.
Release 5.0.1.3
System5.0.1.3
Stacking
Description
User Impact
Under certain conditions 5 or more ports
identified as stacking ports can cause
transmission errors even if the stacking
links are not up.
Low
This problem happens infrequently and setting those ports back to Ethernet mode
has corrected the problem.