Loading...
5. Hold the display built-in self test button until the test starts.
Power-Supply Unit Built-in Self-Test
Built-in Self-Test (BIST) helps determine if the power-supply unit is working. To run self-test diagnostics on the power-supply
unit of a desktop or all-in-one computer, see the knowledge base article 000125179 at www.dell.com/support.
System-diagnostic lights
This section lists the system-diagnostic lights of your OptiPlex 5400 All-in-One.
Table 21. System-diagnostic lights
Blinking pattern
Problem description Suggested resolutionAmber White
1 1 TPM detection failure
Replace the system board.
1 2 Unrecoverable SPI Flash
Failure
Replace the system board.
1 5 EC unable to program i-Fuse
Replace the system board.
1 6 Generic catch-all for
ungraceful EC code flow
errors
Disconnect all power source
(AC, battery, coin cell) and
drain flea power by pressing
and holding down power
button for 3~5 seconds.
2 1 CPU failure
Run the Dell Support
Assist/Dell Diagnostics
tool.
If problem persists,
replace the system board.
2 2 System board failure (included
BIOS corruption or ROM
error)
Flash latest BIOS version
If problem persists,
replace the system board.
2 3 No memory/RAM detected
Confirm that the memory
module is installed
properly.
If problem persists,
replace the memory
module.
2 4 Memory/RAM failure
Reset and swap memory
modules among the slots.
If problem persists,
replace the memory
module.
2 5 Invalid memory installed
Reset and swap memory
modules among the slots.
If problem persists,
replace the memory
module.
2 6 System board/Chipset Error
Replace the system board.
2 7 LCD failure (SBIOS message)
Replace the LCD module.
Troubleshooting 105