EasyManua.ls Logo

Dell PowerConnect 2816 - Page 66

Dell PowerConnect 2816
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66 Update with your book title
Figure 6-7. Integrated Cable Test for Copper Cables
Port
— The port to which the cable is connected.
Test Result
— The cable test results. Possible values are:
No Cable
— There is no cable connected to the port.
Open Cable
— The cable is connected on only one side.
Short Cable
— The cable is 2 meters long.
OK
— The cable passed the test.
Fiber Cable
— A fiber cable is connected to the port.
Cable Fault Distance
— The distance from the port where the cable error occurred.
Last Update
— The last time the port was tested.
Approximate Cable Length
— The approximate cable length. This test can only be performed when
the port is up and operating at 1 Gbps.
Performing a Cable Test
1
Ensure that both ends of the copper cable are connected to a device.
2
Open the
Integrated Cable Test for Copper Cables
page.
3
Click
Test Now
.
The copper cable test is performed, and the results are displayed on the
Integrated Cable Test for
Copper Cables
page.

Table of Contents