EasyManua.ls Logo

Dell PowerConnect 2816 - Page 68

Dell PowerConnect 2816
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68 Update with your book title
Loss of Signal
— Indicates if a signal loss occurred in the cable.
Data Ready
— The transceiver has achieved power up and data is ready.
Displaying Optical Transceiver Diagnostics Test Results Table
1
Open the
Optical Transceiver Diagnostics
page.
2
Click
Show All
.
The test is run and the Virtual Cable Test Results Table opens with the following columns:
Temp
— Internally measured transceiver temperature.
Voltage
— Internally measured supply voltage.
Current
— Measured TX bias current.
Output Power
— Measured TX output power in milliwatts.
Input Power
— Measured RX received power in milliwatts.
TX Fault
— Transmitter fault.
Finisair transceivers do not support the transmitter fault diagnostic testing.
LOS
— Loss of signal.
Data Ready
— The transceiver has archived power up and data is ready.
N/A
— Not Available, N/S - Not Supported, W - Warning, E - Error.
Fiber Optic analysis feature works only on SFPs that support the digital diagnostic standard SFF-4872.

Table of Contents