EasyManua.ls Logo

Dell PowerConnect M6220 - Page 52

Dell PowerConnect M6220
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 Switching Configuration
uplink ports should be active; otherwise, all the internal ports in the Group will be brought down. By
default, the minimum active uplinks for a Group is 1, which means at least one uplink port should be
active for the Aggregator Group to be active.
console(config)#port-aggregator group 2
console(config-aggregator-2)#minimum active uplinks 2
console(config-aggregator-2)#
Example #12: Show Group MAC Address Table
Use the show bridge address-table [port-aggregator group < GroupId >] command to show the MAC
address table for a particular aggregator group.
[port-aggregator group <Group Id>
is an optional
parameter in the command and, if not specified, shows all the MAC entries in all the Groups.
console#show bridge address-table port-aggregator group 2
Aggregator Group: 2
Aging time is 300 Sec
VLAN MAC Address Port Type
----- ---------------- ------ --------------------
3 0006.2932.814D 1/g2 Static
1001 0006.2932.814B 1/g17 Static
Example #13: Show Group VLAN Table
Use the show vlan [port-aggregator group < GroupId >] command to show the VLAN table for a
particular aggregator group.
[port-aggregator group <Group Id>
is an optional parameter in the
command and, if not specified, shows all the MAC entries in all the Groups.
console#show vlan port-aggregator group 2
Aggregator Group: 2
VLAN AggregatorGroup Type Authorization
----- ---------------- ------ -------------
3 2 Static Required
1000 2 Static Required
console#show vlan