22 Using the Baseboard Management Controller
www.dell.com | support.dell.com
Table 1-17. BMC Watchdog Timer Commands (NETFUN: 06H, 07H)
Commands NetFn CMD O/M Supported
Reset Watchdog Timer App 22H M Yes
Set Watchdog Timer App 24H M Yes
Get Watchdog Timer App 25H M Yes
Table 1-18. Chassis Commands (NETFUN: 00H, 01H)
Commands NetFn CMD O/M Supported
Get Chassis Capabilities Chassis 00H M Yes
Get Chassis Status Chassis 01H M Yes
Chassis Control Chassis 02H M Yes
Chassis Reset Chassis 03H N No
Chassis Identify Chassis 04H O Yes
Set Front Panel Button
Enables
Chassis 0AH N No
Set Chassis Capabilities Chassis 05H N No
Set Power Restore Policy Chassis 06H O Yes
Set Power Cycle Interval Chassis 0BH O Yes
(Default: 10 seconds)
Get System Reset Cause Chassis 07H N No
Restart Cause
[3:0] AH = Soft reset
(e.g. CTRL-ALT-DEL)
Set System Boot Options Chassis 08H O Yes
Get System Boot Options Chassis 09H O Yes
Get POH Counter Chassis 0FH M No
Table 1-19. Event Commands (NETFUN: 04H, 05H)
Commands NetFn CMD O/M Supported
Set Event Receiver S/E 00H M Yes
Get Event Receiver S/E 01H M Yes
Platform Event (“Event Message”) S/E 02H M Yes