About Your System 27
0086h Yes ATAPI 6 Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0087h Yes ATAPI 7 Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0120h Yes CPU1 Thermal Failure due to
PROCHOT#
Ensure that the processor
heat sinks are properly
installed.
See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.
0121h Yes CPU2 Thermal Failure due to
PROCHOT#
Ensure that the processor
heat sinks are properly
installed.
See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.
0122h Yes CPU3 Thermal Failure due to
PROCHOT#
Ensure that the processor
heat sinks are properly
installed.
See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.
Code Log in BMC Cause Corrective Actions