28 About Your System
0123h Yes CPU4 Thermal Failure due to
PROCHOT#
Ensure that the processor
heat sinks are properly
installed.
See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.
0150h Yes Processor failed BIST Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0151h Yes Processor failed BIST Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0152h Yes Processor failed BIST Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0153h Yes Processor failed BIST Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0160h Yes CPU1 Processor missing
microcode
A BIOS update is required.
If the problem persists, see
"Getting Help" on page 143.
0161h Yes CPU2 Processor missing
microcode
A BIOS update is required.
If the problem persists, see
"Getting Help" on page 143.
Code Log in BMC Cause Corrective Actions