Drive-status indicator pattern (RAID only) Condition
Steady green Drive online
Flashes green for three seconds, amber for
three seconds, and then turns off after six
seconds
Rebuild stopped
uSATA SSD indicator codes
Figure 10. uSATA SSD indicators
1. uSATA SSD activity indicator 2. uSATA SSD status indicator
3. uSATA SSD
NOTE: If the SSD is in the Advanced Host Controller Interface (AHCI) mode, the status indicator (on
the right side) does not function and remains off.
Table 10. Drive status indicator codes
Drive-status indicator pattern Condition
Flashes green twice per second Identifying drive or preparing for removal.
Off Drive ready for insertion or removal.
NOTE: The drive status indicator remains off until
all hard drives are initialized after the system is
turned on. Drives are not ready for insertion or
removal during this time.
Flashes green, amber, and turns off Predicted drive failure
Flashes amber four times per second Drive failed
Steady green Drive online
Flashes green for three seconds, amber for
three seconds, and turns off after six seconds
Rebuild aborted