Dell
PowerEdge T410 Technical Guide 22
5.4 Environmental Specifications
Table 6 summarizes the environmental specifications for the PowerEdge T410.
Environmental Specifications Table 6.
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
Note: For altitudes above 2950 feet, the
maximum operating temperature is derated
1°F/550 ft.
-40° to 65°C (-40° to 149°F) with a maximum
temperature gradation of 20°C per hour
20% to 80% (non-condensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (non-condensing) with a maximum
humidity gradation of 10% per hour
0.25 Grms at 3–200Hz for 15 minutes
1.54 Grms at 3–200Hz for 15 minutes
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31G for 2.6ms in
the operational orientation
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71G for up to 2ms
-16 to 3048m (-50 to 10,000ft) Note: For
altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550ft
-16 to 10,600m (-50 to 35,000ft)
Airborne contaminant level
Class G1 or lower as defined by ISA-S71.04-1985 (G1 maximum corrosive contaminant levels
measured at ≤ 50% relative humidity)
5.5 Maximum Input Amps
The power supply or power supplies are equipped with automatic input voltage detection.
5.6 ENERGY STAR Compliance
ENERGY STAR
®
qualified configurations can be accessed from the ENERGY STAR Compliance results
landing page on Dell.com.