48 About Your System
SATA port
x
device auto-
sensing error
SATA port
x
device
configuration
error
SATA port
x
device error
The drive connected to the
specified SATA port is faulty.
Replace the faulty drive.
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" or "Troubleshooting
a Hard Drive" for the
appropriate drive(s) installed
in your system.
Shutdown failure General system error. See "Getting Help."
The amount of
system memory has
changed
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory."
Table 1-2. System Messages (continued)
Message Causes Corrective Actions
book.book Page 48 Tuesday, September 15, 2009 10:08 AM