EasyManuals Logo

Dell S3048-ON Deployment Guide

Dell S3048-ON
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 1
S4048-ON Leaf 2
interface port-channel1
description Isilon Node 1
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 1
spanning-tree port type edge
interface port-channel3
description Isilon Node 2
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 3
spanning-tree port type edge
interface port-channel5
description Isilon Node 3
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 5
spanning-tree port type edge
interface port-channel101
description Server 1
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 101
spanning-tree port type edge
interface port-channel102
description Server 2
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 102
spanning-tree port type edge
interface port-channel1
description Isilon Node 1
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 1
spanning-tree port type edge
interface port-channel3
description Isilon Node 2
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 3
spanning-tree port type edge
interface port-channel5
description Isilon Node 3
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 5
spanning-tree port type edge
interface port-channel101
description Server 1
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 101
spanning-tree port type edge
interface port-channel102
description Server 2
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 102
spanning-tree port type edge
The downstream interfaces will be configured in the next section. Dell recommends asymmetrical flow control
(rx on tx off) on S4048-ON leaf switches which have sufficient egress buffers to reduce packet drops and
resulting retransmissions. This feature should be applied to all host interfaces that support flow control. In
OS10EE this is enabled by default, in OS9 it must be configured. Flow control commands are added below
for reference; however, they are not required in OS10EE.

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+