28 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 1
S4048-ON Leaf 2
interface ethernet1/1/1
description Isilon Node 1-10gige-1
no shutdown
channel-group 1 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/3
description Isilon Node 2-10gige-1
no shutdown
channel-group 3 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/5
description Isilon Node 3-10gige-1
no shutdown
channel-group 5 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/17
description Server 1-1
no shutdown
channel-group 101 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/19
description Server 2-1
no shutdown
channel-group 102 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/1
description Isilon Node 1-10gige-2
no shutdown
channel-group 1 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/3
description Isilon Node 2-10gige-2
no shutdown
channel-group 3 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/5
description Isilon Node 3-10gige-2
no shutdown
channel-group 5 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/17
description Server 1-2
no shutdown
channel-group 101 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/19
description Server 2-2
no shutdown
channel-group 102 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
The two upstream layer 3 interfaces connected to the spine switches are configured. Assign IP addresses per
Table 3. Configure a loopback interface to be used as the router ID. This is used with BGP.

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+