EasyManua.ls Logo

Dell S4128-ON - Apply Policies and VLAN ID to Edge Ports; Save DCB Configuration

Dell S4128-ON
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configure Data Center Bridging (DCB) (optional)
15 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704
3.11 Apply policies and VLAN ID to all switch edge ports
OS10(config)# interface range ethernet 1/1/1-1/1/54
OS10(conf-range-eth1/1/1-1/1/54)# switchport mode trunk
OS10(conf-range-eth1/1/1-1/1/54)# switchport trunk allowed vlan <vlan-id>
OS10(conf-range-eth1/1/1-1/1/54)# service-policy input type network-qos <policy-
map-name>
OS10(conf-range-eth1/1/1-1/1/54)# service-policy output type queuing <queuing-
policy-name>
OS10(conf-range-eth1/1/1-1/1/54)# ets mode on
OS10(conf-range-eth1/1/1-1/1/54)# qos-map traffic-class <queue-map-name>
OS10(conf-range-eth1/1/1-1/1/54)# priority-flow-control mode on
OS10(conf-range-eth1/1/1-1/1/54)# exit
OS10(config)#
3.12 iSCSI enable
OS10(config)# iscsi enable
OS10(config)# iscsi session-monitoring enable
OS10(config)# exit
3.13 Save configuration
OS10# copy running-configuration startup-configuration
3.14 Show commands to verify DCBx, ETS, and PFC status on individual
ports
OS10# show lldp dcbx interface ethernet 1/1/<port-number>
OS10# show lldp dcbx interface ethernet 1/1/<port-number> pfc detail
OS10# show lldp dcbx interface ethernet 1/1/<port-number> ets detail
3.15 Configure additional switches
Repeat the commands from section 3 to configure DCB on additional switches.