Chapter 7 Servo Parameters|ASDA-A&A+ Series 
7-50    
Revision April 2009 
P1 - 61 
 
GR8  High Resolution Output Pulse Number  Communication Addr.: 013DH
Default: 7  Related Section: N/A 
Applicable Control Mode: Pt   
Unit: -   
Range: 0 ~ 7 
Settings: 
This function is for ASDA-A+ series only. Please refer to P1-46 for explanation. 
 
P1 - 62 
 
COKT 
Delay Time of Internal Position Command 
Completed Output Signal 
Communication Addr.: 013EH
Default: 0  Related Section:  
Applicable Control Mode: Pr  DO CMDOK(12) in Table 7.B 
Unit: ms   
Range: 0 ~ 200 
Settings: 
This parameter is used to delay the output time of digital output, CMDOK (Internal position 
command completed output) when the servo drive has detected the internal position command 
has been completed.  
If this parameter is set to 0, when DO ZSPD=1, the internal position command which is triggered 
by DI CTRG will be accepted. If this parameter is not set to 0, when DO CMDOK=1, the internal 
position command which is triggered by DI CTRG will be accepted. 
Please see DO CMDOK(12) in Table 7.B for explanation. 
 
P1 - 63 
 
Reserved  Communication Addr.: 013FH
 
P1 - 64 
 
Reserved  Communication Addr.: 0140H
 