Chapter 7 Servo Parameters|ASDA-A&A+ Series 
7-12    
Revision April 2009 
Position Control 
Control 
Mode 
Parameter  Name  Function  Default Unit
Pt  Pr  S  T 
Related 
Section of 
User 
Manual 
P1-01● 
CTL  Control Mode and Output Direction  0 
pulse
r/min
N-m
{  {  {  { 
6.1 
P1-02▲ 
PSTL  Speed and Torque Limit  0  N/A
{  {  {  { 
6.6 
P1-46▲ 
GR3  Encoder Output Pulse Number  1  pulse
{  {  {  { 
--- 
P1-55  MSPD  Maximum Speed Limit 
rated 
speed
r/min
{  {  {  { 
--- 
1st ~ 3rd Torque Command 
P1-12  
~ P1-14 
TQ1 ~ 
3 
1st ~ 3rd Torque Limit 
100 % 
{  {  {  { 
6.4.1 
P2-50  DCLR  Pulse Deviation Clear Mode  0  N/A
{  { 
  --- 
External pulse control command (Pt mode) 
P1-00▲ 
PTT  External Pulse Input Type  2  N/A
{ 
  6.2.1 
P1-44▲ 
GR1 
Electronic Gear Ratio (1st 
Numerator) (N1) 
1 pulse
{  { 
  6.2.5 
P1-45▲ 
GR2 
Electronic Gear Ratio 
(Denominator) 
1  pulse
{  { 
  6.3.6 
P2-60 GR4 
Electronic Gear Ratio (2nd 
Numerator) (N2) 
1 pulse
{  { 
 Table 7.A 
P2-61 GR5 
Electronic Gear Ratio (3rd 
Numerator) (N3) 
1 pulse
{  { 
 Table 7.A 
P2-62 GR6 
Electronic Gear Ratio (4th 
Numerator) (N4) 
1 pulse
{  { 
 Table 7.A 
Internal pulse control command (Pr mode) 
PO1H 
~ 
PO8H 
1st ~ 8th Position command for 
Rotation 
P1-15 
~ P1-30 
PO1L ~ 
PO8L 
1st ~ 8th Position command for 
Pulse 
0 N/A  
{ 
  6.2.2 
P2-36 
~ P2-43 
POV1 
~ POV8 
Moving Speed Setting of 1st ~ 8th 
Position 
1000 r/min  
{ 
  6.2.2 
P1-33● 
POSS
 
Position Control Mode (Pr) 
0 N/A  
{ 
  6.2.2 
P1-47 HMOV Homing Mode  00  N/A
{  {  {  { 
12.8 
P1-48 HSPD1 
1st Speed Setting of High Speed 
Homing 
1000 r/min
{  {  {  { 
12.8 
P1-49 HSPD2 
2nd Speed Setting of Low Speed 
Homing 
50 r/min
{  {
  {  { 
12.8 
P1-50  HOF1  Homing Offset Rotation Number 
0 
rev
{  {
  {  { 
--- 
P1-51  HOF2  Homing Offset Pulse Number 
0 
pulse
{  {
  {  { 
--- 
P1-62 COKT 
Delay Time of Internal Position 
Command Completed Output 
Signal 
0 ms  
{ 
  --- 
Call 1(800)985-6929 for Sales