Chapter 7 Servo Parameters|ASDA-A&A+ Series 
7-60    
Revision April 2009 
P2 - 31 
 
AUT1  Auto Mode Responsiveness Level  Communication Addr.: 021FH
Default: 44  Related Section:  
Applicable Control Mode: ALL  Section 5.6, Section 6.3.6 
Unit: N/A 
Range: 0 ~ FF (0 ~ FF: 0 indicates the lowest setting and F indicates the highest setting (total 16 
settings available))   
Settings: 
not used
B
 
ASDA-A series: 
This parameter allows the users to set the stiffness setting of easy mode and the 
responsiveness level of auto-tuning mode. Users can control the stiffness and responsiveness 
according to application condition. When the setting value is higher, the stiffness and the 
responsiveness is higher. 
A: Stiffness setting of easy mode 
B: Responsiveness level of auto-tuning mode 
 
ASDA-A+ series: 
This parameter allows the users to set the responsiveness level setting of auto-tuning mode. 
Users can control the responsiveness according to application condition. When the setting value 
is higher, the responsiveness is higher. 
A: No function 
B: Responsiveness level of auto-tuning mode 
 
NOTE
 
1)  This parameter is activated by P2-32. 
2)  Please refer to Section 5.6 for the tuning procedure and the related settings. 
 
 
 
 
 
 
 
 
 
 
Call 1(800)985-6929 for Sales