FRONT MENU OPERATION SM3300
20 / 30 DELTA ELEKTRONIKA B.V. rev. Jan. 2022
6.3.3 PROTECTION
ACCESS SECURITY
CHANGE KEY
Select the 4 digit access key.
Default setting is '0000'.
In case of a forgotten access key see troubleshooting,
chapter 8.
LOCK OPTIONS
Select which functions are blocked with the 'LOCK'
function.
Possible settings are 'Menu' and 'Menu &
Controls'.
Default setting is 'Menu & Controls'.
UNLOCK OPTIONS
Select how to unlock the unit. To make a selection, first
the 4 digit access key must be entered.
Possible settings are 'With Key' and 'Without Key'.
Default setting is 'Without Key'.
LIMITS
VOLTAGE LIMIT
Select the setting for the Voltage limit.
Possible settings are 'DISABLED' and 'FIXED VALUE'.
Default setting is 'DISABLED'.
CURRENT LIMIT
Select the setting for the Current+ limit.
Possible settings are 'DISABLED' and 'FIXED VALUE'.
Default setting is 'DISABLED'.
6.3.4 INTERFACES
LAN
ADDRESS
Select / View the present IP-address.
The default setting is 169.254.0.2.
SUBNETMASK
Select / View the present Subnet-mask.
The default setting is 255.255.0.0.
GATEWAY
Select / View the present Gateway-address.
The default setting is 169.254.0.1.
DHCP
Select the setting for DHCP.
Possible settings are 'Enabled' and 'Disabled'.
Default settings is 'Enabled'.
IP-VERSION
View the IP-version.
For firmware package P0120, this version is V4.
MAC ADDRESS
View the unique MAC-address.
The address is in the range of F4:E1:42:xx:xx:xx.
SLOTS
OVERVIEW
Shows the optional installed interfaces in Slot1, 2, 3 and 4.
6.4
FIRMWARE UPDATING
Check the version of the firmware in the unit via Menu >
System Info > Unit > Version.
Go to and check if there is new firmware available via
Products -> SM3300 -> Downloads.
Download the new firmware package to the computer.
Connect the unit to the above computer via LAN and open the
web interface using an internet browser.
The web interface is found by entering the IP-address of the
unit in the address bar of the browser. The IP-address is
found via Menu > Interfaces > LAN > Address.

Other manuals for Delta Elektronika SM3300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM3300 Series and is the answer not in the manual?

Delta Elektronika SM3300 Series Specifications

General IconGeneral
BrandDelta Elektronika
ModelSM3300 Series
CategoryPower Supply
LanguageEnglish

Related product manuals