Troubleshooting
55
ERROR
CODE
DESC.
TROUBLESHOOTING /
CUSTOMER ACTIONS
E-0-1-2
Reverse
Polarity
Battery is connected the
wrong way around. Check the
battery connections. This error
automatically clears once the
condition has been corrected.
E-0-1-3
Battery
does
not take
current
Battery voltage is detected but
the charger is unable to charge
the battery. This can be due to
an electrical device connected
between the charger and the
battery, which passes through
voltage but not current. Verify
correct set up with OEM.