Troubleshooting
54
ERROR
CODE
DESC.
TROUBLESHOOTING /
CUSTOMER ACTIONS
E-0-0-1
E-0-2-1
High
Battery
Voltage
Error
Battery Voltage is too high
to charge. Check the battery
voltage and cable connections.
Check battery size and condition
(could be too full to charge). This
error automatically clears once
the condition has been corrected.
E-0-0-2
E-0-2-2
Low
Battery
Voltage
Battery Voltage is too low to
charge. Check the battery
voltage and cable connections.
Check battery size and condition.
This error automatically clears
once the condition has been
corrected.
E-0-0-3
Charge
Timeout
Charge Timeout caused by battery
pack not reaching required
voltage within safe time limit.
Charger output reduced due to
high temperatures. Possible
causes include poor battery
health, very deeply discharged
battery, poorly connected
battery, or extra loads. Possible
solutions include replacing the
battery pack, checking the DC
connections, disconnecting
parasitic loads, and operating
at lower ambient temperatures.
This error automatically clears
once the charger is reset by
cycling DC.
Table 5-1
10 MOST COMMON
ERROR CODES

Other manuals for Delta-q IC SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta-q IC SERIES and is the answer not in the manual?

Delta-q IC SERIES Specifications

General IconGeneral
BrandDelta-q
ModelIC SERIES
CategoryBattery Charger
LanguageEnglish

Related product manuals