QuiQ Charger Troubleshooting
47
pack, and the pack is of questionable status,
reset the charger by disconnecting AC
power for 30 seconds, and then reconnect
the AC to start a new charge cycle. After
a few charge cycles, this problem could
stop occurring as the pack recovers.
•
This fault must be cleared manually by
unplugging the AC power and waiting
30 seconds before reconnecting the AC
power.
CHECK BATTERY
Flashes (Red):
This fault indicates the battery pack could
not be trickle charged up to the minimum
level required for the normal charge cycle
to be started.
•
Check that none of the battery pack
connections between modules are
reversed or incorrectly connected.
•
Check that one or more cells in the battery
are not shorted.
•
Confirm that the nominal battery pack
voltage is the same as the battery charger
voltage.