QuiQ Charger Troubleshooting
47
pack, and the pack is of questionable status,
reset the charger by disconnecting AC
power for 30 seconds, and then reconnect
the AC to start a new charge cycle. After
a few charge cycles, this problem could
stop occurring as the pack recovers.
•
This fault must be cleared manually by
unplugging the AC power and waiting
30 seconds before reconnecting the AC
power.
CHECK BATTERY
Flashes (Red):
This fault indicates the battery pack could
not be trickle charged up to the minimum
level required for the normal charge cycle
to be started.
•
Check that none of the battery pack
connections between modules are
reversed or incorrectly connected.
•
Check that one or more cells in the battery
are not shorted.
•
Confirm that the nominal battery pack
voltage is the same as the battery charger
voltage.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta-q QUIQ Series and is the answer not in the manual?

Delta-q QUIQ Series Specifications

General IconGeneral
Input Voltage85-265 VAC
IP RatingIP66
Input Frequency45-65 Hz
Storage Temperature-40°C to +85°C
Cooling MethodNatural Convection
Operating Temperature-20°C to 50°C
ProtectionOvertemperature
Agency ApprovalsUL, CE
CommunicationCAN bus