Error
code
Description
CPU
status
ERROR LED indicator
ON
Blinking
fast
Blinking
normally
Blinking
slowly
OFF
19E7 Timeout on the slave error control Continue V
19E8 The node IDs of master and slave are duplicated. Continue V
19F3 Error in the configuration Continue V
19F4 CANopen communication is in the BUS-OFF state.
Continue V
19FB The sending registers exceed the range. Continue V
19FC The receiving registers exceed the range. Continue V
2001
Not
using the FCOMP card or not in the right mode
for the ASDA-
A2 while using the CANopen
communication instruction.
Continue V
2003
The device used in the program excee
ds the device
range or is illegal.
Continue V
200A
Invalid instruction
Stop
V
200B
The operand n or the other constant operands K/H
exceed the range.
Continue V
200C The operands overlap. Continue V
200D
The binary to binary-coded decimal conversion
is
incorrect.
Continue V
200E
The string does not end with 00.
Continue
V
2012
Incorrect division operation
Continue
V
2013
The value exceeds the range of values which can
be represented by the floating-point numbers.
Continue V
2014
The task designated by the TKON or YKOFF
instruction is incorrect, or exceeds the range.
Continue V
2017
The instruction BREAK is written outside of the
FOR-NEXT loop.
Continue V
2027
No such position planning table number or the
format is incorrect.
Continue V
2028
The high speed output instruction is being
executed. Only one instruction can be executed at
a time.
Continue V
2030
During the execution of CSFO instruction, the
output frequency exceeds the upper limit.
Continue V
2031
During the execution of CSFO instruciotn, when
the output frequency is set to 0, but even after 2
seconds, the output is still not complete.
Continue V
6004 The IP address filter is set incorrectly. Continue V
600D
RJ45 port is not connected.
Continue
V
6010
The number of MODBUS TCP connections
exceeds the range.
Continue V
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS228R-A and is the answer not in the manual?

Delta AS228R-A Specifications

General IconGeneral
BrandDelta
ModelAS228R-A
CategoryControl Unit
LanguageEnglish

Related product manuals