ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-65
P1-31 Reserved
P1-32 LSTP Motor Stop Mode
Address: 0140H
0141H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 0x20
Data Size:
16-bit
Format:
Hexadecimal
Settings:
Not in use
Selection of executing dynamic brake
Not in use
Selection of executing dynamic brake: Stop Mode when Servo Off or
Alarm (including EMGS) occurs.
0: Execute dynamic brake
1: Motor free run
2: Execute dynamic brake first, then execute free run until it stops
(The motor speed is slower than P1-38).
When PL and NL occur, please refer to event time setting value of P5-
03 for determining the deceleration time. If the setting is 1 ms, it can
stop instantaneously.
P1-33 Reserved
P1-34 TACC Acceleration Constant of S-Curve
Address: 0144H
0145H
Operational
Interface:
Panel / Software Communication
Related Section:
6.3.3
Default:
200
Control
Mode:
S
Unit:
ms

Table of Contents

Other manuals for Delta ASD-A2-4523 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2-4523 Series and is the answer not in the manual?

Delta ASD-A2-4523 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2-4523 Series
CategoryServo Drives
LanguageEnglish

Related product manuals