ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-147
P4-xx Diagnosis Parameters
P4-00
ASH1 Fault Record (N)
Address: 0400H
0401H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET.
P4-01
ASH2 Fault Record (N-1)
Address: 0402H
0403H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last second abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET