EasyManuals Logo

Delta ASD-A2-4523 Series User Manual

Delta ASD-A2-4523 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #333 background imageLoading...
Page #333 background image
Chapter 8 Parameters ASDA-A2
8-82 Revision February, 2017
P1-63 FRCT Friction Compensation
Address: 017EH
017FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
PTPRS
Unit
ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Settings
Setup smoothing constant of friction compensation.
P1-64 PCCT
Analog Position Command: Activation
Control
Address: 0180H
0181H
Operational
Interface
Panel/Software Communication
Related Section: N/A
Default
0x00
Control
Mode
PT
Unit
--
Range
0 x00~ 0x11
Data Size
32-bit
Format
Hexadecimal
Settings
X:
0: Disable the function of position command which is issued by
analog
1: Enable the function of position command which is issued by
analog

Table of Contents

Other manuals for Delta ASD-A2-4523 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2-4523 Series and is the answer not in the manual?

Delta ASD-A2-4523 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2-4523 Series
CategoryServo Drives
LanguageEnglish

Related product manuals