Chapter 8 ParametersASDA-A2R Series
8-72 Revision December, 2014
Settings
In position mode (PT), if the deviation pulse number is smaller
than the setting range (the setting value of parameter P1-54),
DO.TPOS is ON.
In position register (PR) mode, if the deviation between the target
position and the actual motor position is smaller than the setting
range (the setting value of parameter P1-54), DO.TPOS is ON.
P1-55 MSPD Maximum Speed Limit
Address: 016EH
016FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Same as the rated speed of each model
Control
Mode
ALL
Unit
Permanent magnet synchronous rotary
motor: rpm
Permanent magnet synchronous linear
motor:
3
10
m/s
Range
0 ~ max.speed
Data Size
16bit
Format
DEC
Settings
The default of the max. speed of servo motor is set to the rated
speed.
P1-56 OVW Output Overload Warning Level
Address: 0170H
0171H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
120
Control
Mode
ALL
Unit
%
Range
0 ~ 120
Data Size
16bit
Format
DEC
Settings
The setting value is 0 ~ 100, if the servo motor continuously
outputs the load and is higher than the setting proportion (P1-56),
the early warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2R-0221 Series and is the answer not in the manual?

Delta ASD-A2R-0221 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2R-0221 Series
CategoryServo Drives
LanguageEnglish

Related product manuals