Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-73
P1-57 CRSHA
Motor Crash Protection (torque
percentage)
Address: 0172H
0173H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
%
Range
0 ~ 300
Data Size
16bit
Format
DEC
Settings
Setup protection level (for the percentage of rated torque, set the
value to 0 means to disable the function, set the value to 1 or
number above means to enable the function)
P1-58 CRSHT Motor Crash Protection Time
Address: 0174H
0175H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
1
Control
Mode
ALL
Unit
ms
Range
0 ~ 1000
Data Size
16bit
Format
DEC
Settings
Setup the protection time:
When it reaches the level, AL030 occurs after exceeding the
protection time.
NOTE
This function is only suitable for non-contactable application, such
as electric discharge machines. (please setup P1-37 correclty).
P1-59 MFLT Analog Speed Command
Address: 0176H
0177H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0.0 0
Control
Mode
S

Table of Contents