Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-187
Range:
-100000000 ~ +100000000
Data Size:
32bit
Format:
DEC
Settings:
This parameter goes with the selection of P5-88, U=4 (E-cam will
disengage if it exceeds the moving distance):
fter disengaging, it does not enter the Stop status but
pre-engaged status. The lead pulse is determined by this
parameter.
The pulse number sent by the Master must exceed the setting
value of this parameter so that E-cam will engage again.
In other words, E-cam will engage not until the lead pulse is
ignored.
If the symbol of this parameter is +, it means the received
positive pulse will be regarded as the lead pulse.
If the symbol of this parameter is -, it means the received
negative pulse will be regarded as the lead pulse.
P5-93 CSDS
Motion Control Macro Command:
Command Parameter # 4
Address: 05BAH
05BBH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
-2147483648 ~ +2147483647
Data Size:
32bit
Format:
DEC
Settings:
Before issuing the macro command, the relevant parameters # 4
must be set in advance.
The function of the parameter is determined by the macro
command. Not every macro command has its relevant
parameters.
P5-94 CSDS
Motion Control Macro Command:
Command Parameter # 3
Address: 05BCH
05BDH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0