P5-08 SWLP Forward Software Limit
Address: 0510H
0511H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
2147483647
Control
Mode
PR
Unit
PUU
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
In PR mode, if the motor rotates in forward direction and its
command position exceeds the setting value of P5-08, it will
trigger AL283.
P5-09 SWLN Reverse Software Limit
Address: 0512H
0513H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
-2147483648
Control
Mode
PR
Unit
PUU
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
In PR mode, if the motor rotates in reverse direction and its
command position exceeds the setting value of P5-09, it will
trigger AL285.