ASDA-M Chapter 8 Parameters
Revision December, 2014 8-147
P5-08 SWLP Forward Software Limit
Address: 0510H
0511H
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
2147483647
Control
Mode:
PR
Unit:
PUU
Range:
-2147483648 ~ +2147483647
Data Size:
32bit
Format:
DEC
Settings:
In PR mode, if the motor rotates in forward direction and its
command position exceeds the setting value of P5-08, it will
trigger AL283.
P5-09 SWLN Reverse Software Limit
Address: 0512H
0513H
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
-2147483648
Control
Mode:
PR
Unit:
PUU
Range:
-2147483648 ~ +2147483647
Data Size:
32bit
Format:
DEC
Settings:
In PR mode, if the motor rotates in reverse direction and its
command position exceeds the setting value of P5-09, it will
trigger AL285.