ASDA-M Chapter 8 Parameters
Revision December, 2014 8-157
Default
2500
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-31 AC11
Acceleration/Deceleration Time
(Number #11)
Address: 053EH
053FH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
3000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-32 AC12
Acceleration/Deceleration Time
(Number #12)
Address: 0540H
0541H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
5000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500