ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-181
P5-42 DLY2
Delay Time After Position Completed (Number
#2)
Address: 0554H
0555H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
200
Control
Mode:
PR
Unit:
ms
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
The 3
rd
Delay Time of PR mode
P5-43 DLY3
Delay Time After Position Completed (Number
#3)
Address: 0556H
0557H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
400
Control
Mode:
PR
Unit:
ms
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
The 4
th
Delay Time of PR mode
P5-44 DLY4
Delay Time After Position Completed (Number
#4)
Address: 0558H
0559H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
500
Control
Mode:
PR
Unit:
ms

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals