Chapter 6 Control Mode of Operation ASDA-A2
6-12 Revision February, 2017
Settings
Acceleration / Deceleration Constant of S-Curve:
P1-34: Set the acceleration time of acceleration / deceleration of
trapezoid-curve
P1-35: Set the deceleration time of acceleration / deceleration of
trapezoid-curve
P1-36: Set the smoothing time of S-curve acceleration and
deceleration
P1-34, P1-35 and P1-36 can be set individually. Even when P1-36 is
set to 0, it still has acceleration / deceleration of trapezoid-curve.
NOTE
1When the source of speed command is analog, and P1-36 is set to
0, it will disable S-curve function.
2When the source of speed command is analog, the max. range of
P1-36 will be set within 10000 automatically.
6.2.5 Electronic Gear Ratio
Related parameters:
P1-44
GR1 Gear Ratio (Numerator) (N1)
Address: 0158H
0159H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.5
Default
1
Control
Mode
PTPR
Unit
Pulse
Range
1 ~ (2
29
-1)
Data Size
32-bit
Format
Decimal
Settings
Please refer to P2-60~P2-62 for the setting of multiple gear ratio
(numerator).
NOTE
1. In PT mode, the setting value can be changed when Servo ON.
2. In PR mode, the setting value can be changed when Servo OFF.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals