Chapter 6 Control Mode of Operation ASDA-A2
6-22 Revision February, 2017
Unit
0.1 Hz
Range
10 ~ 1000
Data Size
16-bit
Format
Decimal
Example
150= 15 Hz
Settings
The setting value of the first low-frequency vibration suppression. If P1-
26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression Gain
(1)
Address: 0134H
0135H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
0
Control
Mode
PT / PR
Unit
-
Range
0 ~ 9 (0: Disable the first low-frequency filter)
Data Size
16-bit
Format
Decimal
Settings
The first low-frequency vibration suppression gain. The bigger value it
is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested
to set the value to 1.
P1-27
VSF2 Low-frequency Vibration Suppression (2)
Address: 0136H
0137H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
1000
Control
Mode
PT / PR
Unit
0.1 Hz
Range
10 ~ 1000
Data Size
16-bit
Format
Decimal
Example
150 = 15 Hz